UPC E, continued
UPC E0 and UPC E1 Expand
UPC E Expand expands the UPC E code to the 12 digit, UPC A format. Default = Off.
On
* Off
UPC E0 and UPC E1 Addenda Required
When Addenda Required is set to on, the scanner will only read UPC E bar codes that have addenda. Default = Not Required.
Required
* Not Required
UPC E0 and UPC E1 Addenda Separator
When this feature is on, there is a space between the data from the bar code and the data from the addenda. When turned off, there is no space.
Default = On.
* On
Off