Laser Emulation Polarity
The Polarity can be sent as standard with white bars high, or reversed with black bars high. Default = White High.
* White High
Black High
Laser Emulation Idle
The idle describes the state of the scanner when no data is being transmitted. When in Non Decoded mode, you must set the scanner’s idle state to match the idle state for the device to which the scanner is connected. Default = Idle High.
Idle Low
* Idle High
Secondary Trigger Mode
Manual Trigger: You must press the scanner trigger to scan. When not scanning, idle power is maintained. Default = Manual Trigger.
* Manual Trigger
Automatic Trigger: The scanner scans continuously at full power.
Automatic Trigger
Presentation Mode: The LEDs are off until a bar code is presented to the scanner. Then the LEDs turn on automatically to read the code. Presentation Mode uses ambient light to detect the bar codes.
Presentation Mode
6 - 4 | IT5600/IT5800 User’s Guide |