Interfunction Delay
An interfunction delay of up to 495 milliseconds may be placed between the transmission of each segment of the message string. Scan the Interfunction Delay bar code below, then scan the number of milliseconds and the SAVE bar code using the Programming Chart inside the back cover of this manual.
Prefix
Scanned Data
Suffix
STX | 1 | HT | 2 | 3 4 | 5 | CR | LF |
Interfunction Delays
Interfunction Delay
To remove this delay, scan the Interfunction Delay bar code, then set the number of steps to 0. Scan the SAVE bar code using the Programming Chart inside the back cover of this manual.
Intermessage Delay
An intermessage delay of up to 495 milliseconds may be placed between each scan transmission. Scan the Intermessage Delay bar code below, then scan the number of milliseconds and the SAVE bar code using the Programming Chart inside the back cover of this manual.
1st Scan Transmission 2nd Scan Transmission Intermessage Delay
Intermessage Delay
To remove this delay, scan the Intermessage Delay bar code, then set the number of steps to 0. Scan the SAVE bar code using the Programming Chart inside the back cover of this manual.
4 - 6 | IT5600/IT5800 User’s Guide |