IT5600/IT5800 User’s Guide 7 - 31

RSS Expanded, continuedRSS Expanded

RSS Expanded Message Length

Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 4-74. Minimum Default = 4, Maximum Default = 74.
EANUCC Emulation
The imager can automatically format the output from any EAN•UCC data carrier
to emulate what would be encoded in an equivalent UCC/EAN-128 or
RSS+Composite symbol. EAN•UCC data carriers include UPC-A and UPC-E,
EAN-13 and EAN-8, ITF-14, UCC/EAN-128, and EAN•UCC RSS and
Composites. If UCC/EAN-128 Emulation is selected, the AIM Symbology
Identifier will be reported as “]C1”. If RSS Emulation is selected, the AIM
Symbology Identifier will be reported as “]e0.” Any application that accepts
EAN•UCC data can be simplified since it only needs to recognize one data carrier
type.
Default = EAN•UCC Emulation Off
.
* On
Off
Minimum Message Length
Maximum Message Length
RSS Emulation
128 Emulation
* EAN•UCC Emulation Off