Good Read Delay

This sets the minimum amount of time before the scanner can read another bar code. Default = No Delay.

*No Delay

Short Delay (500 ms)

Medium Delay (1000 ms)

Long Delay (1500 ms)

User-Specified Good Read Delay

If you want to set your own length for the good read delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save.

User-Specified Good Read Delay

Trigger Modes

Manual/Serial Trigger

You can activate the scanner either by pressing the trigger, or using a serial trigger command (see Trigger Commands on page 11-4). When in manual trigger mode, the scanner scans until a bar code is read, or until the trigger is released.

When in serial mode, the scanner scans until a bar code has been read or until the deactivate command is sent. In serial mode, the scanner can also be set to turn itself off after a specified time has elapsed (see Read Time-Out, which follows).

* Manual/Serial Trigger

IT5600/IT5800 User’s Guide

3 - 3

Page 45
Image 45
Hand Held Products IT5800, IT5600 manual Trigger Modes, User-Specified Good Read Delay, Manual/Serial Trigger