Note: Code 93 must be enabled to use this example.
A - Code 39
B - Code 128
C - Code 93
You would set up the sequence editor with the following command line:
SEQBLK62999941FF6A999942FF69999943FF
The breakdown of the command line is shown below:
SEQBLKsequence editor start command 62 code identifier for Code 39
9999 code length that must match for Code 39, 9999 = all lengths
41start character match for Code 39, 41h = “A” FF termination string for first code
6A code identifier for Code 128
9999 code length that must match for Code 128, 9999 = all lengths
42start character match for Code 128, 42h = “B”
FFtermination string for second code
69 code identifier for Code 93
9999 code length that must match for Code 93, 9999 = all lengths 43 start character match for Code 93, 43h = “C”
FF termination string for third code
To program the previous example using specific lengths, you would have to count any programmed prefixes, suffixes, or formatted characters as part of the length. If you use the example on page
SEQBLK62001141FF6A001242FF69001143FF
3 - 12 | IT5600/IT5800 User’s Guide |