Top Vent - Horizontal Termination

V1 Minimum

H1 Maximum

Elbow only

NOT ALLOWED

1 ft.

305 mm

2 ft.

610 mm

2 ft.

610 mm

4 ft.

1.22 m

3 ft.

914 mm

8 ft.

2.44 m

4 ft.

1.22 m

10 ft.

3.05 m

5 ft.

1.52 m

16 ft.

4.88 m

V1 + H1 = 30 ft. (9.14 m) Maximum

Note: A 6 in. (152 mm) section of straight flue must be attached to the heater before a 90° elbow.

USE SLP SERIES COMPONENTS ONLY

WARNING

Fire Risk. Explosion Risk.

Do NOT pack insulation or other combustibles between ceiling firestops.

ALWAYS maintain specified clearances around venting and firestop systems.

• Install wall shield and ceiling firestops as speci- fied.

Failure to keep insulation or other material away from vent pipe may cause fire.

Example: DVP pipe 3 ft. (1 m) min. vertical = 11 ft. (3.35 m) max. horizontal

SLP pipe 7 ft. (2.13 m) min. vertical = 11 ft. (3.35 m) max. horizontal

H1

V1

Figure 7.4

Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF2089-980 Rev. o • 6/12

27

Page 27
Image 27
Heat & Glo LifeStyle 350TRSI-AUF Top Vent Horizontal Termination, USE SLP Series Components only, V1 Minimum H1 Maximum