5 Framing and Clearances

A. Selecting Appliance Location

When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1).

WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.

Due to high temperatures, the appliance should be locat- ed out of traffic and away from furniture and draperies.

NOTICE: Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference.

1 in. (25 mm) GAP TO WALL ON EACH SIDE

NOTE: THE REAR STANDOFF MAY NEED

TO BE REMOVED WHEN VENTING AT 45º

 

A

1/2 in.

G

 

(13 mm)

 

 

K

 

J

ALCOVE

E

 

INSTALLATION

A

B

 

 

 

 

C

 

 

TOP FLUE

 

 

ONE 90º ELBOW

 

 

REAR FLUE,

 

 

 

HORIZONTAL TERMINATION

 

 

 

TWO 90º ELBOWS

 

REAR FLUE

 

N

REAR FLUE

ONE 90º ELBOW

 

 

 

NO ELBOWS

B

 

B

 

B

 

D

 

 

 

 

 

 

 

 

F

 

3 in. (76 mm)

 

 

 

I

 

D

 

H

 

 

 

D

 

 

L

C

L

M

 

 

 

A

B

C

D

E

F

G

H

I

J

K

L

M

N

 

 

350TRSI-AUF

in.

40-1/4

34

56

48-1/2

See Section D.

16-1/2

13-1/2

7-1/2

34-3/4

27-3/4

36

42-5/8

5-7/8

68-3/4

 

 

350TRSILP-AUF

mm

1023

864

1423

1232

Mantel Projections

419

343

191

883

705

914

1082

149

1737

 

Figure 5.1 Appliance Locations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF2089-980 Rev. o • 6/12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 20
Image 20
Heat & Glo LifeStyle 350TRSILP-AUF, 350TRSI-AUF owner manual Framing and Clearances, Selecting Appliance Location