4 Getting Started

Installer Guide

 

A. Typical Appliance System

NOTICE: Illustrations and photos reflect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual

Note: Dual venting configurations ARE NOT allowed. Appliance MUST be vented EITHER vertically OR horizontally.

NON-COMBUSTIBLE ROOF FLASHING

MAINTAINS MINIMUM CLEARANCE

AROUND PIPE (SECTION 10.J)

VENT PIPE (SECTIONS 7 & 8)

CEILING FIRESTOP ON FLOOR OF ATTIC (SECTION 8.C and 10.G)

FRAMING/HEADER (SECTION 5.C)

GAS LINE (SECTION 11)

Figure 4.1 Typical System

HORIZONTAL

TERMINATION CAP (SECTION 10.H)

VERTICAL TERMINATION CAP

(SECTION 10.L)

STORM COLLAR (SECTION 10.K)

VENT PIPE PENETRATES ROOF

PREFERABLY WITHOUT AFFECTING

ROOF RAFTERS (SECTION 8)

ATTIC INSULATION SHIELD (NOT SHOWN) MUST BE USED HERE TO KEEP INSULATION AWAY FROM VENT PIPE IF ATTIC IS INSULATED (SECTION 8.D)

FRAMING HEADED OFF IN CEILING JOISTS (SECTION 8.C)

REQUIRED ISOLATION SWITCH: AS5601

LOCATION WITHIN 1 METER OF FIREPLACE,

SUBJECT TO MANTEL PIECE, ETC. CHECK

TO ENSURE IT REMAINS CLEAR ON ANY

MANTEL PIECE INSTALLATION.

OPTIONAL

 

WALL SWITCH

 

SECTION 12.C.

 

HEATER MUST BE INSTALLED AND

MANTEL AND

FLUE PENETRATION COMPLETE

MANTEL LEG

PRIOR TO FINISH SHEETING

(SECTION 5.D)

 

 

SURROUND

 

HEARTH EXTENSION

18

Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF2089-980 Rev. o • 6/12

 

Page 18
Image 18
Heat & Glo LifeStyle 350TRSILP-AUF, 350TRSI-AUF owner manual Getting Started, Typical Appliance System