Rear Vent - Vertical Termination

One Elbow

V1

H1

Figure 7.16

Two Elbows

V1

V1 Minimum

H1 Maximum

1 ft.

305 mm

3 ft.

914 mm

2 ft.

610 mm

6 ft.

1.83 m

3 ft.

914 mm

8 ft.

2.44 m

4 ft.

1.22 m

11 ft.

3.35 m

5 ft.

1.52 m

12 ft.

3.66 m

V1 + H1 = 36 ft. (10.97 m) Maximum

H1 = 12 ft. (3.66 m) Maximum

USE DVP SERIES COMPONENTS ONLY

V1 Minimum

H1 + H2

Maximum

2 ft.

610 mm

Back to Back 90º Elbows

 

 

 

 

 

1 ft.

310 mm

3 ft.

 

915 mm

2 ft.

610 mm

4 ft.

 

1.22 m

3 ft.

914 mm

8 ft.

 

2.44 m

4 ft.

1.22 m

10 ft.

 

3.05 m

V1 + H1 = 32 ft. (9.75 m) Maximum

H1 + H2 = 9 ft. (2.74 m) Maximum

USE DVP SERIES COMPONENTS ONLY

INSTALLED

HORIZONTALLY H1

H2

Figure 7.17

36

Heat & Glo • 350TRSI-AUF, 350TRSILP-AUF2089-980 Rev. o • 6/12

 

Page 36
Image 36
Heat & Glo LifeStyle 350TRSILP-AUF, 350TRSI-AUF Rear Vent Vertical Termination One Elbow Two Elbows, Minimum Maximum