5 Framing and Clearances

5 Framing and Clearances

A. Selecting Appliance Location

When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1).

WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.

Due to high temperatures, the appliance should be locat- ed out of traffic and away from furniture and draperies.

NOTICE: Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. Illustrations/diagrams are not drawn to scale. Actual installation may vary due to individual design preference.

It is important to follow the framing and finishing instruc- tions step by step to ensure proper placement of fireplace in the surrounding framing/finishing materials. For addi- tional information and considerations for the active con- vection technology in regards to appliance location and framing, see Section 9.

A

A

E

1 IN.

A. Selecting Appliance Location 1 IN.

 

B

 

C TOP VENT

45°

ONE 90° ELBOW

 

B

D

ALCOVE

INSTALLATION

Note: Consider installation of the active con- vection blower when determining appliance location. See Section 9.C for more detailed information.

TOP VENT

ONE 90° ELBOW

B

F

 

A

B

C

D

E

F

Inches

60-3/8

50

85-3/8

See Section D.

24-1/8

18-3/4

Millimeters

1533

1270

2168

Figure 5.6 & 5.7

613

476

Figure 5.1 Appliance Locations RED40

Heat & Glo • RED40, RED40ST • 2155-900 Rev. o • 7/12