SLOT ON
BLOWER HOUSING
Figure 12.17. Remove Mounting Plate | Figure 12.20. Blower Tab Inserted into Slot on Blower Housing |
11.Attach new blower to mounting plate by fastening the four screws in the appropriate locations. The side of the blower with the label on it must face toward the inside of the appliance. This is the direction of the air flow. See Figure 12.18.
Figure 12.18. Removed Mounting Plate
12.To install new blower back into appliance, reverse the removal procedure. Install blower assembly with the tab toward the rear of the appliance. See Figure 12.19. This tab must insert into slot on blower housing inside the appliance as shown in Figure 12.20.
BLOWER TAB ON
MOUNTING PLATE
Figure 12.19. Blower Tab Toward Rear
Heat & Glo • RED40, RED40ST • | 51 |
|