H. Fixed Glass Assembly

H. Fixed Glass Assembly

WARNING! Risk of Asphyxiation! Handle fixed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches.

DO NOT strike, slam or scratch glass.

DO NOT operate fireplace with glass removed, cracked, broken or scratched.

Replace as a complete assembly.

Removing Fixed Glass Assembly

1.Remove the decorative front.

2.Locate the two spring latches that are on the lower left and right of the fireplace.

3.Use both index fingers to release spring latches. See Figure 14.3.

4.Allow glass to tilt forward. Grasp glass on the upper return lip of glass frame and tilt glass “out” and “down”. Lower gently to rest on side supports. See Figure 14.3. Allow top of glass assembly to tilt forward. Lift glass assembly “up” and “out”.

Replacing Fixed Glass Assembly

1.Locate glide tabs on lower left and right corners.

2.Place glass bottom resting on right and left support. Tilt top of glass assembly toward fireplace.

3.Allow of the gasketing of the glass assembly to touch the face of the fireplace. Lift the glass “up” and “in” to upper glass clip flanges.

4.Hold bottom of the glass as you allow the glass as- sembly to seat over the two lower glass clips. See Figure 14.3.

5.Assure proper left and right placement of glass and engage both lower spring latches.

GLASS SIDE

SUPPORT

GLASS CLIP

GLASS TAB

Figure 14.3 Fixed Glass Assembly

I. Install the Mesh

A mesh front is included with the RED40 and RED40ST. For installation instructions, see section 13.D.

J. Air Shutter Setting

Air shutter settings may be adjusted by a qualified install- er at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shutter for longer vertical runs. See Figure 14.4.

Loosen the 1/4 in. screw.

Twist shutter to adjust

Shutter may be open for longer horizontal vent runs.

Do not close the air shutter more than 1/16 in. for NG or 1/4 in. for LP.

Tighten the screw.

NOTICE: If sooting occurs, provide more air by opening the air shutter.

Figure 14.4 Air Shutter

Air Shutter Settings

RED40/RED40ST

NG

LP

GRANITE KIT

1/16 in.

1/4 in.

LIGHT KIT

1/16 in.

1/4 in.

PORCELAIN KIT

1/16 in.

1/4 in.

60

Heat & Glo • RED40, RED40ST • 2155-900 Rev. o • 7/12

Page 60
Image 60
Heat & Glo LifeStyle RED40ST H. Fixed Glass Assembly, I. Install the Mesh, J. Air Shutter Setting, Air Shutter Settings