Heat & Glo LifeStyle RED40ST Top Vent - Vertical Termination, Venting with 3 elbows, 1 ft

Models: RED40ST RED40

1 82
Download 82 pages 42.72 Kb
Page 30
Image 30
Manual background

Top Vent - Vertical Termination

Venting with 3 elbows

Note: 12 inches minimum vertical is required prior to attaching any elbow to the appliance.

V2

H1

H2

INSTALLED

HORIZONTALLY

V1 + V2 Minimum

H1 + H2 Maximum

1 ft.

305 mm

2 ft.

610 mm

2 ft.

610 mm

4 ft.

1219 mm

3 ft.

914 mm

9 ft.

2743 mm

4 ft.

1219 mm

12 ft.

3658 mm

5 ft.

1524 mm

15 ft.

4572 mm

V1+ V2 + H1+ H2= 63 ft. (19.2 m) Maximum

H1 + H2 = 23 ft. (7.1 m) Maximum

Note: Use DVP Series components only.

V1

Figure 7.10

30