12 Electrical Information
A. Wiring Requirements
NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA
Code CSA C22.1.
•Wire the appliance junction box to
•A
•Low voltage and 110 VAC voltage cannot be shared within the same wall box.
WARNING! Risk of Shock or Explosion! DO NOT wire 110V to the valve or to the appliance wall switch. Incorrect wiring will damage controls.
B. IntelliFire Ignition System Wiring
•Wire the appliance junction box to 110 VAC for proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction box to a switched circuit. Incorrect wiring will override IPI safety lockout.
•Refer to Figure 12.5, IntelliFire Pilot Ignition (IPI) Wiring Diagram.
•This appliance is equipped with an IntelliFire control valve which operates on a 3 volt system.
•Plug the
C. Optional Accessories Requirements
•This appliance ships standard with a wall switch and may use a remote control.
Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories.
Optional Remote Control Receiver
The junction box, control module, light controller and wall switch receiver can be accessed thru the air space between the firebox front and the
Note: If the fan is moved from one side to the other, the junction box must also move. See appropriate configuration in relation to the valve in Figure 12.3. The valve does not move.
FAN ASSEMBLY
JUNCTION BOX
Figure 12.1. Valve Cavity (Lower Access Panel Removed)
THERMODISC | VALVE |
MODULE
Figure 12.2. Valve Cavity
FAN |
|
INSTALLED ON |
|
LEFT |
|
JUNCTION | |
BOX |
|
OPTIONAL |
|
REMOTE | CONTROL |
| |
| MODULE |
| VALVE |
| FAN |
| INSTALLED ON |
| RIGHT |
| JUNCTION |
| BOX |
| VALVE |
| CONTROL |
| MODULE |
| OPTIONAL |
| REMOTE |
Figure 12.3. Controls Location Diagram
46 | Heat & Glo • RED40, RED40ST • |