12 Electrical Information

12 Electrical Information

A. Wiring Requirements

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric

Code CSA C22.1.

Wire the appliance junction box to 110-120 VAC. This is required for proper operation of the appliance.

A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

Low voltage and 110 VAC voltage cannot be shared within the same wall box.

WARNING! Risk of Shock or Explosion! DO NOT wire 110V to the valve or to the appliance wall switch. Incorrect wiring will damage controls.

B. IntelliFire Ignition System Wiring

Wire the appliance junction box to 110 VAC for proper operation of the appliance.

WARNING! Risk of Shock or Explosion! DO NOT wire IPI controlled appliance junction box to a switched circuit. Incorrect wiring will override IPI safety lockout.

Refer to Figure 12.5, IntelliFire Pilot Ignition (IPI) Wiring Diagram.

This appliance is equipped with an IntelliFire control valve which operates on a 3 volt system.

Plug the 3-volt AC transformer into the appliance junction box to supply power to the appliance.

C. Optional Accessories Requirements

This appliance ships standard with a wall switch and may use a remote control.

Wiring for optional Hearth & Home Technologies approved accessories should be done now to avoid reconstruction. Follow instructions that come with those accessories.

Optional Remote Control Receiver

The junction box, control module, light controller and wall switch receiver can be accessed thru the air space between the firebox front and the lower-front finishing cover panel. The decorative front and glass assembly must be removed to access these components. See Figure 12.1.

Note: If the fan is moved from one side to the other, the junction box must also move. See appropriate configuration in relation to the valve in Figure 12.3. The valve does not move.

FAN ASSEMBLY

JUNCTION BOX

Figure 12.1. Valve Cavity (Lower Access Panel Removed)

THERMODISC

VALVE

MODULE

Figure 12.2. Valve Cavity

FAN

 

INSTALLED ON

 

LEFT

 

JUNCTION

BOX

 

OPTIONAL

 

REMOTE

CONTROL

 

 

MODULE

 

VALVE

 

FAN

 

INSTALLED ON

 

RIGHT

 

JUNCTION

 

BOX

 

VALVE

 

CONTROL

 

MODULE

 

OPTIONAL

 

REMOTE

Figure 12.3. Controls Location Diagram

46

Heat & Glo • RED40, RED40ST • 2155-900 Rev. o • 7/12

Page 46
Image 46
Heat & Glo LifeStyle RED40ST Electrical Information, A. Wiring Requirements, B. IntelliFire Ignition System Wiring