WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping materials could ignite and will interfere with proper operation of doors and louvers.
WARNING! Risk of Fire! DO NOT install drywall or other combustible materials directly onto the factory- installed
Decorative facing material thickness is measured from the face of the
The mesh front can be installed such that it overlaps
Refer to Section 1.E and 1.F of this manual for definition and qualifications and definition of
Specific requirements for each method if installation are described below and on the following pages of this section.
Non-Combustible Finish Materials
0 - 1 inch thickness-Overlap Fit Method
The mesh front is designed to overlap finish materials 0 inches to 1 inch thick. See Figure 13.7.
NOTICE: This one inch maximum not only includes the decorative finish materials (marble, tile, slate, etc) but also the thin set, lath and adhesive used to attach the decorative finish material.
The
| |
| FACTORY INSTALLED |
| |
SIDE FINISH |
|
BOARD (2) |
|
47 IN. WIDTH |
|
FACTORY INSTALLED | |
= NO SCREWS IN THIS AREA | = 2 IN. MAX. SCREW LENGTH |
Figure 13.8
| |
| |
| |
| COMBUSTIBLE |
| FRAMING |
| 1/2 IN. THICK |
| WALL SHEATHING |
| |
1/2 IN. | |
| |
| |
| BOARD |
1 IN. |
|
| |
| ON FRONT FACE (SIDE VIEW) |
| = AIR SPACE |
Figure 13.7 Overlap Fit Method
56 | Heat & Glo • RED40, RED40ST • |