C. Active Convection Technology

C. Active Convection Technology

The fireplace appliance has been provided with an active convection blower. The blower is required to keep lower control chamber component temperatures at an ideal op- erating temperature. The blower also provides for more efficient use of appliance heat by assisting the convection air around the firebox and back into the room. A four inch flexible duct kit has been provided with the appliance. One end of the flex duct will connect to the fan bracket assembly located in the lower control chamber. See Figure 9.6, Detail A. The other end will terminate to an interior wall of the house. The intake grille panel provided with the appliance must be used. See Figure 9.2 and Figure 9.5.

Note: The blower is essential for keeping components and the appliance environment in safe operating temperatures.

Note: Refer to Section 12.C if the active convection blower is to be moved to the right side.

WARNING! Risk of Fire! DO NOT terminate blower vent into an attic, crawl space, or the appliance chase. Vent must terminate on an adjacent, interior wall.

H1 MAX. = 8 FT.

H1 + V1 + H2 = 8 FT.

MAX. = TWO 90° BENDS

INLET CONVECTION AIR MAY BE VENTED IN

ANY DIRECTION,INCLUDING DOWNWARD.

H1

24-IN. MIN.

CLEARANCE FROM

INTAKE TO

OBJECTS = 24 IN. MIN.

V1

LOUVERED VENT

H2

NOTE: The 6 in. x 5.5 in. intake vent cover provided with the appliance must be used.

Figure 9.5. Active Convection Technology Duct and Termination.

4 INCH

 

 

CONVECTION

 

 

AIR DUCT

 

 

8 FT.

 

 

MAXIMUM

 

 

MAX. OF 2

 

 

90° BENDS

 

 

8 FT.

 

 

MAXIMUM

 

 

SEE DETAIL A

 

 

4 INCH

ZIP TIE

 

CONVECTION

 

(INCLUDED WITH FLEX DUCT)

 

AIR DUCT

 

 

 

 

4 INCH FLEX DUCT

 

 

DETAIL A

 

 

 

FAN BRACKET ASSEMBLY

Figure 9.6. Active Convection Technology Duct Venting Specifications.

 

 

Heat & Glo • RED40, RED40ST • 2155-900 Rev. o

• 7/12

37

 

Page 37
Image 37