0 Inches to 4 Inches Thick Inside Fit Method

Non-Combustible Finish Materials

0 Inches to 4 Inches Thick Inside Fit Method

The mesh decorative front is approved for inside fit ap- plications. Non-combustible finishing materials up to 4 inches thick can be installed around the Mesh front (left, right, top, and bottom). The inside fit method requires an additional 2 in. of 1/2 in. thick non-combustible building material (not supplied with fireplace) to be installed on the left and right sides flush with the factory installed non- combustible board.

Ensure that no non-combustible finish materials are in- stalled within 1-1/2 inches of top and bottom and 1-3/16 inches from right and left sides of fireplace opening. This will ensure adequate clearance for required mesh front. See Figure 13.11.

Refer to Section 1.E and 1.F of this manual for definition and qualifications and definition of non-combustible and combustible materials.

1/2 IN. THICK

WALL SHEATHING

0-4 IN.

1/2 IN.

15-1/2 IN.

16-1/2 IN.

13-1/8 IN.

1/2 IN.

0- 4 IN.

DRYWALL OR

EQUIVALENT (1/2 IN.)

Figure 13.9 Inside Fit Method

 

45-1/2 IN.

 

 

42-3/4 IN.

 

13-1/8 IN.

1-1/2 IN.

 

 

 

 

FIREPLACE VIEWING AREA

16-1/2 IN.

1-3/16 IN.

 

1-3/16 IN.

 

 

 

1-1/2 IN.

 

= CLEARANCE FROM VIEWING AREA TO NON-COMBUSTIBLE FINISHING MATERIAL (INSIDE FIT METHOD)

Figure 13.10 Noncombustible Surface Finishing Material 0-4 Inches Thick-Inside Fit Method

57

Heat & Glo • RED40, RED40ST • 2155-900 Rev. o • 7/12

 

Page 57
Image 57
Heat & Glo LifeStyle RED40 Non-CombustibleFinish Materials, Inches to 4 Inches Thick Inside Fit Method, 42-3/4IN, 13-1/8IN