B. Securing and Leveling the Appliance

B. Securing and Leveling the Appliance

WARNING! Risk of Fire! Prevent contact with:

Sagging or loose insulation

Insulation backing or plastic

Framing and other combustible materials

Block openings into the chase to prevent entry of blown- in insulation. Make sure insulation and other materials are secured.

DO NOT notch the framing around the appliance standoffs. Failure to maintain air space clearance may cause overheating and fire.

For details on setting the appliance in the framing, refer to section 13.B. The diagram shows how to properly position, level, and secure the appliance (see Figure 9.1). Nailing tabs are provided to secure the appliance to the framing members.

Bend out the two nailing tabs on each side.

Place the appliance into position.

Keep nailing tabs flush with the framing.

Level the appliance from side to side and front to back.

Shim the appliance as necessary. It is acceptable to use wood shims underneath the appliance.

Secure the appliance to the framing by using nails or screws through the nailing tabs.

Figure 9.2 shows the fireplace installed on the floor. However, this fireplace can be elevated off the floor provided that the fireplace is properly supported by framing materials and the ceiling clearances are maintained.

Setting the Fireplace into the Framing

The left and right nailing tabs were designed as a means to ensure the fireplace is mounted flush with the framing materials.

1.Bend out all 4 nailing tabs.

2.Screw each nailing tab to the adjoining framing ma- terial. Ensure that the one inch air space clearance is maintained on the sides and back of the fireplace. See Figure 5.4 and Figure 5.5.

NAILING

TAB

NAILING

TAB

Figure 9.3 Nailing Tabs

Figure 9.4 Nailing Tabs

Shipping Position

Installation Position

Note: Active Convection Tech-

nology must not pull air from

outside. Termination must draw

air from an interior room.

6 IN. X 5.5 IN. REQUIRED

GRILLE PANEL

NAILING TABS

BOTH SIDES

DUCT COLLAR

ASSEMBLY

POSSIBLE LOCATIONS FOR VENT

TERMINATION OF ACTIVE CONVECTION

TECHNOLOGY

TERMINATION INTO INTERIOR ROOM

Figure 9.2 Proper Positioning, Leveling And Securing Of An Appliance

36

Heat & Glo • RED40, RED40ST • 2155-900 Rev. o • 7/12

Page 36