D. Facing Material

D. Facing Material

Facing and/or finishing materials must not interfere with air flow through louvers, operation of louvers or doors, or access for service.

Facing and/or finishing materials must never overhang into the glass opening.

Observe all clearances when applying combustible materials.

11-1/4 IN.

 

3-1/2 IN.

 

3-1/2 IN.

 

 

COMBUSTIBLE

 

FRAMING

 

1/2 IN. THICK

 

WALL SHEATHING

7-1/4 IN.

 

1/2 IN.

20-3/4 IN.

 

FACTORY-SUPPLIED

 

NON-COMBUSTIBLE

 

BOARD

1 IN.

 

 

NON-COMBUSTIBLE BOARD

 

ON FRONT FACE (SIDE VIEW)

 

= AIR SPACE

Figure 13.5 Framing and Framing Materials-RED40

 

10-1/4 IN.

3-1/2 IN.

3-1/2 IN.

 

1/2 IN. THICK

 

WALL SHEATHING

 

COMBUSTIBLE

 

FRAMING

7-1/4 IN.

 

 

1/2 IN.

1/2 IN.

20-3/4 IN.

 

FACTORY-SUPPLIED

 

NON-COMBUSTIBLE

 

BOARD (2)

 

NON-COMBUSTIBLE BOARD

 

ON FRONT FACE

 

SIDE VIEW

 

= AIR SPACE

Figure 13.6 Framing and Framing Materials-RED40ST

Heat & Glo • RED40, RED40ST • 2155-900 Rev. o • 7/12