Heat & Glo LifeStyle RED40ST Top Vent - Horizontal Termination - continued, Venting with 2 elbows

Models: RED40ST RED40

1 82
Download 82 pages 42.72 Kb
Page 26
Image 26
1. Top Vent - Horizontal Termination - (continued)

1. Top Vent - Horizontal Termination - (continued)

Top Vent - Horizontal Termination

Venting with 2 elbows

V1 Minimum

H1 + H2 Maximum

1 ft.

305 mm

2 ft.

610 mm

2 ft.

610 mm

6 ft.

1829 mm

3 ft.

914 mm

9 ft.

2743 mm

4 ft.

1219 mm

12 ft.

3658 mm

V1 + H1 + H2 = 63 ft. (19.2 m) Maximum

H1 + H2 = 23 ft. (7.1 m) Maximum

Note: 12 inches minimum vertical is required prior to attaching any elbow to the appliance.

Note: Use DVP Series components only.

H2

H1

 

INSTALLED

HORIZONTALLY

Figure 7.5

V1

26

Heat & Glo • RED40, RED40ST • 2155-900 Rev. o • 7/12

Page 26
Image 26
Heat & Glo LifeStyle RED40ST owner manual Top Vent - Horizontal Termination - continued, Venting with 2 elbows, V1 Minimum