• With type 1 scaling you can specify the percentage of unused space that is to lie below, or to the left of, the isotropic area.

left specifies the percentage of unused space you want to lie to the left of the isotropic area and can be from 0

to 100. If you do not specify the value for left, it is automatically set to the default value = 50%.

bottom specifies the percentage of unused space you want to lie below the isotropic area and can be from 0 to 100. If you do not specify the value for bottom, it is automatically set to the default value = 50%.

(10,10)

P2

P2

 

 

(10,10

Extra space

(0,10)

Extra space

P1(0,0)

SC 0,10,0,10,1,0,0

(10,10)

P2

Extra space

P1

SC0,20,0,10,1,100,100

P2

Extra space

(20,10)

P1

(10,0)

P1(0,0)

 

SC 0,10,0,10,1,100,100

SC 0,20,0,10,1,0,0

You must either specify both left and bottom, or specify neither. However, the printer can only use one of these two parameters at a time, depending where the extra space is on a page. \

• If you do not specify a percentage for unused space to the left or at the bottom, the isotropic area is centred in the rectangle defined by P1 and P2.

Type 2 scaling (point factor scaling) specifies the ratio of graphics units to user units and sets user units coordinates for P1.

Xfactor specifies the number of graphics units that comprise a single user x-axis unit.

Yfactor specifies the number of graphics units that comprise a single user y-axis unit.

Valid values for Xfactor and Yfactor are real numbers.

• An SC command remains in effect until another SC command is issued, until default settings are restored with the DF command or until the printer is initialized with an IN command.

10 '-Scale-'

20 WIDTH "LPT1:", 255

30 LPRINT CHR$(27); "E";

40 LPRINT CHR$(27); "%0B";

50 LPRINT "IN;SP1;"

60 '-- Anisotropic scaling --

70 LPRINT "PA1500,6000;EA3500,8000;"

80 LPRINT "IP1500,6000,3500,8000;SC0,200,0,100,0;PA50,50;CI50;"

90 LPRINT "IN;PA1500,3000;EA3500,5000;"

100 LPRINT "IP1500,3000, 3500,5000;SC0,100,0,200,0;PA50,50;CI50;"

110 LPRINT"IN;PA1300,8200;DT#;LBAnisotropic scaling#";

120'--Isotropic scaling--

130'Left,Bottom= 0,0

140LPRINT "PA4500,6000;EA6500,8000;"

150LPRINT"IP4500,6000,6500,8000;SC0,200,0,100,1,0,0;PA50,50;CI50;"

160'Left, Bottom = 100,100

170LPRINT "IN;PA4500,3000;EA6500,5000;"

180LPRINT"IP4500,3000,6500,5000;SC0,100,0,200,1,100,100;PA50,50;CI50;"

190LPRINT "IN;PA4000,82;DT#;LBIsotrop00ic scaling#";

200LPRINT CHR$(27);"%0A"; 210LPRINT CHR$(27);"E";

220END