Homelite HL-P2500, HL-1660E, HL-2400CE, HL-1450, 2060 FT Fill type, FT n, d, q, Fill type Option

Models: HL-1250 HL-1270N HL-1470N 2400C HL-1050 HL-P2500 2060 HL-1660E HL-1070 HL-1450 HL-2400CE

1 431
Download 431 pages 8 Kb
Page 171
Image 171

10/10/03

FT - Fill type

 

 

FT n(, d(, q))[;]

 

n ; Fill type

d ; option 1

q ; option 2

Sets the fill type, interval and angle when filling an area. This setting is effective for the commands FP, RA, RR, WG and CF.

The value for n must be a clamped integer number

Fill type

Description

Option 1

Option 2

 

 

 

 

1

Solid black (bi-directional fill)

 

 

2

Solid black (single directional fill)

 

 

 

 

 

 

3

hatching (parallel line)

fill interval

fill angle

 

 

 

 

4

cross-hatching

fill interval

fill angle

10

shading

shading level

 

 

 

 

 

11

HP-GL/2 user-defined

raster-fill index

 

 

 

 

 

21

PCL cross-hatching

pattern type

 

 

 

 

 

22

PCL user-defined

pattern ID

 

 

 

 

 

130

shading (one of sixty-four gray scales)

Shading level

 

option 1 for n=3 or 4 is the setting for the interval of the lines in the fill. This is specified in current units.

If d is omitted or 0, it is set to the default value which is 1% of the diagonal distance between P1 and P2.

Option 2 for n=3 and 4 is the setting of the angle for the lines in degrees.

If q is omitted, the fill angle already specified will be used.

The value of q is a clamped real number.

Option 1 for n=10 is the setting for the shading density. It is specified as a percentage from 0 to 100.

Option 2 for n=10 is ignored.

Option 1 for n=11 specifies the HP-GL/2 user-defined raster fill pattern. This uses the index number which is defined by the RF command.

Option 2 for n=11 is ignored.

Option 1 for n=21 specifies the PCL cross-hatch patterns. There are 6 types of PCL cross-hatch patterns.

Option 2 for n=21 is ignored.

Option 1 for n=22, the PCL user-defined patterns defined by the ESC*c#W command with a unique ID code.

Option 2 for n=22 is ignored.

Option 1 for n=130, the 64 gray scale shading density. It is specified as a percentage from 0 to 100.

Option 2 for n=130 is ignored.

10 ' - Fill Type -

20 WIDTH "LPT1:", 255

30 LPRINT CHR$(27); "E";

40 LPRINT CHR$(27); "%0B";

50 LPRINT "IN;SP1;";

60 LPRINT "PA2000,2000;FT;PR2500,300;ER2500,300;"

70 LPRINT "PR0,300;FT3,80,30;RR2500.300;"

80 LPRINT "PR0,300;FT10,36;RR2500,300;ER2500,300;"

90 LPRINT CHR$(27); "%0A";

100 LPRINT CHR$(27); "E";

110END

<Sample 39>

CHAPTER 4 HP-GL/2 - 31

Page 171
Image 171
Homelite HL-P2500, HL-1660E, HL-2400CE, HL-1450, HL-1050, HL-1250, HL-1470N, 2060 FT Fill type, FT n, d, q, Fill type Option