Installation and Setup Guide

On-Board Triggers

Connect field wiring to the desired trigger pin on the 8-pin trigger connector centrally

 

located above the terminal strip.

 

If using 1361X10 transformer and powerline carrier devices, use the SA4120XM-1

 

 

cable (part of 4120TR Trigger Cable). See Wiring the AC Transformer section for

 

transformer connections.

 

If only using the on-board triggers, you can use a 4-wire cable (N4632-4, supplied

with the control) as shown below.

 

 

 

 

 

 

 

8-PIN TRIGGER CONNECTOR

8-PIN TRIGGER CONNECTOR

 

 

 

 

 

 

 

 

KEY

 

 

 

 

 

1

KEY

3

4

5

6

7

8

1

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(RED)

(ORANGE)

(YELLOW)

(GREEN)

(BLUE)

(PURPLE)

(BLACK)

OUTPUT17

+12AUX.

GND(-)

OUTPUT18

DATA

COM

SYNC

OUTPUT 17 (YELLOW)

+12 AUX. (RED)

GND (-) (BLACK)

OUTPUT 18 (GREEN)

SA412OXM-1

CABLE

00-trigcon-003-V1

Figure 15a. On-Board Trigger Connector with SA4120XM-1 Cable for Use With 1361X10 Transformer

4-WIRE CABLE

00-trigcon-005-V2

Figure 15b. On-Board Trigger Connector with 4-Wire Cable for Trigger Use Only

Trigger outputs are normally high, and go low upon programmed condition.

The outputs can be programmed for inverted operation (normally low, go high) using *79 Menu mode.

Program these triggers using *80/*81 Menu modes as you would for any other relay output.

When using these outputs, note:

pin 1 = output number 17 (trigger 1):

15 ohms to ground when closed (output low), open when off (output high, normal default); can be used to reset smoke detector power (must set “output normal low

=yes” in *79 Menu mode, and set for zone type 54, fire zone reset, in *80 Menu mode); or can support 12V relay module (e.g., Altronix AX-RBS)that draws less than 100mA

pin 5 = output number 18 (trigger 2):

100 ohms to ground when closed (output low); open when off (output high, normal default); or can support 12V relay module that draws less than 20mA

UL If on-board triggers are used, the wiring between the control unit and the UL Listed device must be run in conduit, be no more than 3 feet apart and have no intervening barriers or walls.