10-11

Figure 17. Summary of Connections

24-HR BATTERY STANDBY REQUIRED FOR

BATTERY FUSE

 

 

 

8-PIN CONNECTOR

 

 

 

 

 

 

ADEMCO No. 4219

 

 

 

 

 

 

 

 

 

 

4-WIRE SMOKE DETECTOR CONNECTIONS

 

 

 

USED FOR 1361X10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIRE INSTALLATIONS. USE 12V, 17.2AH

 

3A FOR REPLACEMENT,

 

 

 

 

 

 

 

 

WIRED EXPANSION MODULE

 

 

 

 

 

+ 5

 

 

 

 

 

 

BATTERY FOR 600mA AUX POWER. SEE

 

 

 

TRANSFORMER

 

 

 

 

OPTIONAL ADDITIONAL40TOUPFOR ZONES OREITHERFROM( BOTH GROUPS)

 

 

(8 ADD'L EOLR WIRED ZONES)

 

 

 

 

 

 

 

 

 

 

 

 

 

USE SAME VALUE

 

17OUTPUT

 

 

 

 

 

 

 

SET UNIT’S

 

AUX PWR

 

 

 

RELAY

 

 

 

 

 

 

 

 

 

 

 

1)(TRIG.

AUX+12 GND 18OUTPUT 2)(TRIG.

 

 

 

 

 

 

 

-AND/OR-

 

 

 

 

 

 

 

 

 

 

 

INSTRUCTIONS.

 

 

(e.g. ADEMCO No. 90-12)

 

CONNECTIONS AND FOR

 

 

 

 

 

 

 

 

 

 

DIP SWITCH

 

OUTPUT

PROGRAM RELAY

 

BLK

+

RED

BATTERY CAPACITY FOR EMERGENCY

 

 

 

 

 

 

ON-BOARD TRIGGERS

 

 

 

 

 

 

ADEMCO No. 4229

 

 

FOR DEVICE

TERMINALS

AS ZONE TYPE 54

 

 

 

 

BURGLARY STANDBY USE AT LEAST 4 HRS

 

 

 

 

 

SEE INSTRUCTIONS.

(USE SA4120XM-1

 

BLK

(8 ADD'L EOLR WIRED ZONES PLUS 2

 

7 - 15

 

 

 

4

 

 

 

 

 

POWER

 

 

ñ

 

 

 

 

 

1 2

3 4

5

6

7 8

 

RED

 

 

OUTPUT RELAYS)

 

 

SEE

 

 

 

 

 

 

N.C.

 

N.O.

SUPERVISION

CHARGING VOLTAGE

BATTERY

 

BLACK

 

FLYING LEADS

 

 

 

 

 

SYNC

 

 

 

GRN

ADEMCO No. 4204 RELAY MODULE

 

 

 

 

 

UPON FIRE ALARM RESET

 

 

USE N.O.

13.8VDC. MAXIMUM

12V, 4AH

+

+

ñ

 

 

 

 

 

 

COM

TO

 

 

YEL

 

(4 OUTPUT RELAYS)

 

 

 

 

 

 

 

 

 

 

 

VIOLET

CONTACT,

CHARGING CURRENT

 

 

RED

 

FOR BATTERY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO OUTPUT 17

+

 

WHICH CLOSES

 

 

 

 

 

 

 

 

 

 

TRANS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHEN POWER

 

 

 

 

CONNECTION

 

 

 

 

 

 

DATA

 

 

 

 

AND/OR

 

 

 

SET

 

 

 

PROGRAM OUTPUT 17 FOR

 

 

650mA.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"OUT NORM LOW" = YES IN

4-WIRE SMOKE

 

IS APPLIED.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADEMCO 5881* Type

 

 

RECEIVER’S

 

79 MENU MODE AND AS ZONE

OR COMBUSTION

2000

 

SEALED LEAD-ACID TYPE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RF RECEIVER

 

 

DIP SWITCH

 

TYPE 54 IN 80 MENU MODE

DETECTOR

OHMS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

FOR DEVICE

 

 

MAX. CURRENT = 100 mA

 

 

EOLR

 

BATTERY NORMALLY NEED NOT BE

 

 

 

 

 

 

 

 

 

 

 

TO TERM 4

 

BLK

 

 

 

WIRELESS ZONES

 

 

ADDRESS

 

 

 

(UP TO 16 DETECTORS

 

 

 

 

REPLACED FOR AT LEAST 3 YRS.

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

PLUS EOL MODULE)

 

 

 

 

 

 

 

 

RED JUMPER

 

 

 

 

 

TO TERM 5

 

RED

 

 

5881L:

UP TO 8

 

 

 

OF “0”.

 

 

TO ZONE TERM. (+)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN

 

 

 

 

SEE

 

 

 

HEAT

 

 

 

TO DETERMINE TOTAL STANDBY LOAD

 

 

 

 

 

ñ

+

 

 

TO TERM 6

 

GRN

 

 

5881M: UP TO 16

 

 

 

INSTRUCTIONS.

 

(ZONES 2 - 8 ONLY)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5881H: UP TO 56

 

 

 

 

 

 

 

DETECTOR

 

 

 

 

 

 

CUT FOR BELL SUPERVISION.

 

 

 

YEL

 

 

 

 

 

TO ZONE TERM. ( )

 

 

 

ON BATTERY, ADD 100mA TO TOTAL OF

 

 

 

ALSO, CONNECT 2000 OHM

 

TO TERM 7

 

YEL

 

 

*5882 IN CANADA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUX. POWER OUTPUT AND REMOTE

 

 

 

 

RESISTOR DIRECTLY ACROSS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KEYPAD CURRENTS.

 

 

 

 

 

SOUNDER.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USE UL LISTED LIMITED ENERGY

 

1

2

 

3

4

 

 

 

5

 

6

7

8

9

10

11

12

13

14

15

16

 

17

18

 

19

20

 

21

22

23

24

25

CABLE FOR ALL CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLASS 2 PLUG-IN TRANSFORMER

 

 

 

 

 

RETURN)-(

 

}

 

 

 

 

HI

LO

LO

HI

HI

LO

LO

HI

HI

LO

LO

HI

HI

LO

LO

HI

 

}INCOMING}

 

16.5VAC, 25VA

 

 

 

 

 

 

 

 

 

 

 

 

 

(e.g. ADEMCO No. 1321).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIP

RING

TIP

RING

 

(USE No. 1321CN IN CANADA)

 

USAGE, INCLUDING

 

 

 

 

BLK

PWRKEYPADRED:( + )

KEYPADYELLOW:DATA OUT

SMOKEWIRE-2FORUSED DETECTORS

 

 

 

 

• MAXIMUM LOOP RESISTANCE: (EACH ZONE) 300 OHMS (PLUS EOLR)

 

(BROWN) (GRAY)

(GREEN)

(RED)

 

DESCRIBING PROPER INSTALLATION,

 

 

 

 

INDATAGREEN:FROM KEYPAD

 

 

 

 

 

 

 

 

 

 

USE 1361X10 TRANSFORMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HANDSET

 

 

EARTH

IN ACCORDANCE WITH THE NATIONAL

 

 

 

 

 

GROUNDKEYPAD

AUX. POWER

 

 

 

 

1ZONE

 

2ZONE

 

3ZONE

4ZONE

 

 

5ZONE

6ZONE

7ZONE

 

8ZONE

ONLY20P-VISTA

 

 

DOC LOAD NO.: 3

 

GROUND

INTERFACE IN PLACE OF 1321 OR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHONE LINE

1321CN WHEN POWER LINE CARRIER

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TELEPHONE WIRING

SEE

DEVICES ARE BEING USED. (SEE

 

 

 

 

 

 

10.5-13.8VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(VIA RJ31X* JACK AND DIRECT

INSTRUCTIONS

INSTRUCTIONS FOR CONNECTIONS)

 

TO 110VAC

 

 

 

600mA MAX.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOR PROPER

 

 

 

UNSWITCHED

 

 

(500mA MAX.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECT CORD)

GROUNDING

THIS EQUIPMENT SHOULD BE INSTALLED

OUTLET (24HR)+

 

 

 

FOR UL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*CA38A IN CANADA

 

ñ

INSTALLATIONS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIRE PROTECTION ASSOCIATION'S

 

ALARM OUTPUT

BLACK:

ALL OUTPUTS

 

 

 

2000

2000

 

2000

2000

 

2000

2000

2000

2000

 

 

 

 

 

 

STANDARD 72, CHAPTER 2 (NATIONAL

 

ARE POWER

 

 

 

 

 

FOR CONNECTION OF OPTIONAL 4285 OR 4286 VIP

 

 

 

 

 

 

LIMITED.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIRE PROTECTION ASSOCIATION,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODULES TO PHONE TERMINALS, SEE INSTRUCTIONS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BATTERY-MARCH PARK, QUINCY,MA

 

10.5–13.8VDC, 2A MAX.

 

 

 

 

 

 

 

 

OHMS

OHMS

 

OHMS

OHMS

OHMS

OHMS

OHMS

OHMS

WARNING:TO PREVENT RISK OF SHOCK,

02269).

 

 

 

 

 

 

 

 

 

 

 

PRINTED INFORMATION

 

 

(600mA MAX. FOR UL

NOTE:

 

 

 

 

 

 

 

EOLR

EOLR

 

EOLR

EOLR

EOLR

EOLR

EOLR

EOLR

DISCONNECT TELEPHONE LINE AT TELCO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERATION,TESTING, MAINTENANCE,

 

AUX POWER) STEADY

KEYPAD (S)

 

 

REMOTE

 

BE

 

 

 

 

• RESPONSE, ZONES 1-8:10, 350, OR 700 MSEC (PROGRAMMABLE)

JACK BEFORE SERVICING THIS UNIT.

 

CURRENT (IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KEYPADS

 

12

13

14

 

 

 

 

 

 

 

EVACUATION PLANNING AND REPAIR

 

FOR BURGLARY/PANIC,

BOTH

 

 

 

 

 

CAN

 

MAXIMUM NUMBER OF 2-WIRE SMOKE DETECTORS ON ZONE 1 IS 16;

 

COMPLIES WITH FCC RULES, PART 68.

 

 

 

 

 

 

 

 

 

 

 

SERVICE IS TO BE PROVIDED WITH THIS

 

TEMPORAL PULSE

 

 

 

 

AND OTHER

 

 

 

 

DETECTORS MUST HAVE COMPATIBILITY IDENTIFIER AS "A".

 

 

FCC REGISTRATION NO. 5GBUSA-44003-AL-E

 

PARTITIONS)

 

 

 

 

 

 

 

 

EQUIPMENT.

 

 

SOUNDING FOR FIRE.

 

ADDRESSABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RINGER EQUIVALENCE: 0.1B.

 

 

 

AND ALL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAN USE ADEMCO No. 702

 

 

 

DEVICES

 

 

 

 

 

 

 

 

 

 

 

 

POWER SHUTDOWN NOTE:

 

 

 

 

 

 

 

 

OTHER DEVICES

 

 

 

2k

TAMPER

2k

 

 

 

 

 

ZONE

 

 

 

 

 

 

 

CONNECTION OF THE FIRE ALARM

 

SIREN, OR 12V BELL).

 

(e.g. 5800TM,

 

 

 

 

 

 

 

THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.

 

DRAWING

 

 

 

 

CONTACTS

 

 

 

 

 

PAIRS

 

SYSTEM SHUTS DOWN SENSOR

SIGNAL TO A FIRE ALARM

 

 

SEE INSTRUCTIONS.

 

 

4285/4286, LRR,

 

 

 

 

 

10

 

11

 

OPERATION IS SUBJECT TO THE FOLLOWING TWO

 

 

POWER FROM

 

 

 

 

 

 

 

 

 

DETECTION PROCESSING IF

HEADQUARTERS OR A CENTRAL STATION

 

 

 

 

 

 

 

2 / 10

 

 

 

 

 

TERMS 4 & 5

 

 

4219, 4229,

 

 

 

 

 

 

 

 

 

 

 

CONTROL'S VOLTAGE DROPS

CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL

SHALL BE PERMITTED ONLY WITH THE

 

 

 

 

 

 

 

4204, 5881)

 

 

 

 

 

 

 

 

 

 

3 / 11

 

INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY

PERMISSION OF THE LOCAL AUTHORITY

 

 

 

 

 

MUST BE

 

 

 

 

 

 

 

 

 

 

ZONE 2

 

 

4 / 12

 

BELOW 9.6V.

 

 

 

INTERFERENCE RECEIVED, INCLUDING INTERFERENCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HAVING JURISDICTION. THE BURGLAR

 

 

 

 

 

INCLUDED IN

 

REMOTE KEYPADS

 

2k

TAMPER

2k

 

 

 

 

 

5 / 13

 

 

 

 

 

 

THAT MAY CAUSE UNDESIRED OPERATION.

 

FOR COMPLETE

 

 

 

 

CONTACTS

 

 

 

 

3k

 

6 / 14

 

 

 

 

 

 

ALARM SIGNAL SHALL NOT BE

 

 

AUX CURRENT

 

CAN USE 6150 OR 6160

 

 

 

 

 

 

 

 

7 / 15

 

 

 

WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS

CONNECTED TO A POLICE EMERGENCY

 

INFORMATION, SEE

DRAIN

 

 

 

KEYPADS. LOCAL

 

 

 

 

 

 

 

 

 

8 / 16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM. IN ADDITION, THIS SYSTEM MUST BE CHECKED BY A QUALIFIED

 

INSTRUCTIONS K5305-1V2

 

 

 

 

 

 

 

 

 

ZONE 10

 

 

 

 

 

NUMBER.

 

 

CALCULATIONS.

PROGRAMMING

 

 

2k

2k

 

 

 

 

 

 

 

 

TECHNICIAN AT LEAST ONCE EVERY THREE (3) YEARS.

 

 

 

 

 

 

 

 

 

 

 

 

MUST BE DONE WITH A

 

 

 

 

6.2k

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONE 3

ZONE 4

 

 

 

 

 

 

ALL DEVICES AND ACCESSORIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6139/6160, BUT NEED NOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TYPICAL WIRING FOR

 

 

TYPICAL WIRING FOR

USED IN A CANADIAN INSTALLATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REMAIN IN THE SYSTEM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOUBLE BALANCED ZONE

 

 

ZONE DOUBLING

 

MUST BE LISTED FOR USE IN CANADA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(SET TO ADDRESS 16).

 

(VISTA-20P ONLY)

 

 

(VISTA-20P ONLY)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADEMCO VISTA-20P / VISTA-20PSIA SERIES / VISTA-15P / VISTA-15PSIA SERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUMMARY OF CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V20P_V15P-SOC-V5

Page 79
Image 79
Honeywell VISTA-20PSIA, VISTA-15PSIA setup guide Summary of Connections