System Operation

Keypad Functions

The following is a brief list of system commands. For detailed information concerning system functions, refer to the User's Manual. For Touch Screen style keypad users, refer to the separate Touch Screen keypad (AUI) User’s Guide.

Voice Keypads

The 6150V/6160V Voice Keypads provide the following features:

Message Center, which lets the user record and playback one message.

Voice Status, which can announce system status by using the STATUS key.

Voice Chime, which can alert users to the opening of doors/windows while the system is disarmed. Refer to the User Guide for specific procedures for activating and using these features.

Keypad Commands

Function

Description

Silence alarms

Pressing any key will silence the keypad sounder for 10 seconds. Disarming the system will

 

silence both keypad and external sounders.

Quick Arm

If enabled (field ∗21), you can press [#] in place of the system's security code, plus the

 

desired arming key (Away, Stay, Instant, Maximum)

Single-Button arming

If programmed (*57 Function Key menu mode), lettered keys A-D can be used for arming,

 

using options 3-AWAY, 4-STAY, 5-NIGHT-STAY, or 6-Step-Arming

 

If used, no security code is required to arm the system.

Alarm Memory

When the system is disarmed, any zones that were in an alarm condition during the armed

 

period will be displayed. To clear this display, simply repeat the disarm sequence (enter

 

the security code and press the OFF key) again.

Arming Away

Enter code + AWAY [2] or simply press appropriate lettered key on the keypads (see

 

“Single-Button Arming” above). If the “Auto-Stay Arm” feature is enabled (field *84) and

 

the entry/exit door is not opened and closed within the programmed exit delay time, the

 

system will automatically arm in STAY mode if armed from a wired keypad (non-RF

 

device). If the door is opened and closed within the exit delay period, the system arms in

 

AWAY mode.

Arming Stay

Enter code + STAY [3] or simply press appropriate key on the keypads (see “Single-Button

 

Arming” above). See “Arming Away” above for Auto-Stay arming feature.

Arming Night-Stay

Enter code + STAY [3] + STAY [3] or simply press appropriate key on the keypads (see

 

“Single-Button Arming” above).

Arming Instant

Enter code + INSTANT [7].

Arming Maximum

Enter code + MAXIMUM [4] or simply press appropriate lettered key on the keypads (see

 

“Single-Button Arming” above).

Disarming

Enter code + OFF [1]. If entry delay or an alarm is active, you do not need to press

 

OFF.

Bypassing Zones

Enter code + BYPASS [6] + zone number(s).

Forced (Quick) Bypass

To automatically bypass all faulted zones, use the “Quick Bypass” method. Enter code +

 

BYPASS + [#], then wait for all open zones to be displayed. Arm when display indicates

 

“ZONE BYPASSED” and “READY TO ARM”.

Chime Mode

Enter code + CHIME [9]. To turn chime off, enter code + CHIME again.

Activate Output

If relay outputs (via a 4204, or 4229), or Powerline Carrier devices are used, two keypad

Devices

entries available to the user are included. If programmed, these entries can be used to

 

manually activate or deactivate the device(s) for starting or stopping some action, such as

 

turning lights on or off, etc. These keypad entries are:

 

[Security Code] + # + 7 + [2-digit Device #] activates (starts) that device.

 

[Security Code] + # + 8 + [2-digit Device #] deactivates (stops) that device.

6-5