Menu Mode Programming
Start Output Device Mapping by pressing *79 while in Data Programming Mode. ∗79 Menu Mode
|
|
| Device Output Number |
| ENTER OUTPUT NO. | ||
| |||
| 00 = QUIT | xx | |
| [∗] to continue; 00 to quit | ||
|
|
| |
|
|
| |
|
|
| This is the logical (or reference) relay number as used in the system. Relays and |
|
|
| devices are numbered |
|
|
| programmed for inverted output, if required. Use the worksheet on the Programming Form |
|
|
| (printed separately) to organize device numbers. |
17 OUT NORM LOW |
|
0 = NO 1 = YES | 0 |
Output Normally Low (prompt appears only for Triggers 17 and 18)
0 = no (standard default); 1 = yes [∗] to continue
Selecting 0 (no) sets the output level normally high (default setting). Selecting 1 (yes) sets the output normally low.
Output Trigger 17 can be used for resetting
After entry, display returns to Output Number prompt. Use *80 Menu mode to program the function of the trigger.
XXOUTPUT TYPE
DELETE0
Output Type
0 = delete; 1 = relay on 4204/4229 module; 2 = Powerline Carrier device
Select whether this is a relay or a Powerline Carrier
If relay is selected, skip to “B” prompt.
“A”
XX UNIT No.
yy
Unit Number (prompt appears if
[∗] to continue
Enter the unit code (set at the device) and press [∗]. The system returns to the Output Number prompt.
“B”
XXMODULE ADDR
Module Address (prompt appears if relay is selected)
07-15 = predefined address [∗] to continue
Enter the predefined address for this module as listed below. Make sure the module’s DIP switches are set to the selected address.
Module Addresses
| Address | Module | † These addresses apply to |
| 07 | 1st 4229 (with zones |
|
| 08 | 2nd 4229 (with zones |
|
| 09† | 3rd 4229 (with zones |
|
| 10† | 4th 4229 (with zones |
|
| 11† | 5th 4229 (with zones |
|
| 12 | 1st 4204 |
|
| 13 | 2nd 4204 |
|
| 14† | 3rd 4204 |
|
| 15† | 4th 4204 |
|
|
|
|
|
XX REL POSITION
Relay Position
1-4 = relay position [∗] to continue
This is the actual (or physical) relay number with respect to the Relay Module upon which it is located. For 4204 modules, relay numbers are
The system returns to the Output Number prompt for programming the next device.