Disconnect UPS Battery

!CAUTION - The UPS battery must be disconnected before you ship the Thor VM1, Replace UPS Battery (page 4-60)or Replace Front Panel (page 4-58).

Equipment Required

The following equipment is user-supplied:

Torquing tool capable of measuring inch pounds

#2 Phillips screwdriver bit

Disconnect Procedure

1.For convenience, the Thor VM1 can be removed from the Quick Mount Smart Dock, though it is not necessary.

2. If the Thor VM1 remains in the dock, disconnect the power cable from the dock.

3. Shutdown the Thor VM1.

4. Place the Thor VM1 face down on a stable surface.

5. Using a #2 Phillips bit loosen the M3 screws and then remove the tethered access panel with the SIM label. This panel is on the right hand side when the Thor VM1 is face down with the top away from the user.

6. Locate the small push button located just below the SIM card installation slot..

7. Press the push button to disconnect the UPS. The UPS battery maintains its charge but is disconnected from the power circuitry of the Thor VM1.

8. Reattach the access panel, torquing the M3 screws to 4-5 inch pounds using a #2 Phillips bit.

9. When the Thor VM1 is attached to external power, the UPS battery is automatically reconnected.

10. Restart the Thor VM1.