Replace UPS Battery

The UPS battery in the Thor VM1 is field replaceable. Should the UPS battery fail, it can easily be replaced to minimize down- time.

Equipment Required

The following equipment is user-supplied:

Torquing tool capable of measuring inch pounds

#2 Phillips screwdriver bit

Replacement Procedure

!CAUTION - Before replacing the Thor VM1 UPS battery, Disconnect UPS Battery (page 4-55).

1.Place the Thor VM1 on a clean, well-lit surface before performing the front panel replacement.

2.Shutdown the Thor VM1.

3.Remove the Thor VM1 from the Quick Mount Smart Dock.

4.Disconnect UPS Battery (page 4-55).

5.Loosen the twelve (12) captive M3 screws holding the front panel. Use a #2 Phillips bit.

6.Carefully lift the front panel away from the device

7

2

4

6

 

 

9

10

5

1

3

8

 

 

11131214

7. Note the orientation of the UPS battery. Lift the UPS battery out of the battery well and place it outside the well. Do not pull on the wires attaching the battery to the Thor VM1 while lifting the battery.

Wiring

UPS

Foam

Connector

Battery

Pads

8. Locate the retaining tab on the wiring connector for the UPS battery. Press on the tab and gently disconnect the UPS battery wiring from the Thor VM1.

Wiring Connector with Release Tab