Cooling errors

Cooling errors occur when too few fans are installed in the enclosure or when the existing fans are not installed in an effective configuration. Cooling errors can occur on blades, storage blades, or interconnect modules.

To correct a cooling error:

1.Use the arrow buttons to navigate to Fix This, and press OK.

2.Review and complete the corrective action suggested by the Insight Display. In most cases, you must either add fans to the enclosure, correct the fan configuration, or remove the indicated components.

Location errors

Location (installation) errors occur when the component is not installed in the appropriate bay. Location errors can occur on blades, storage blades, power supplies, and fans.

To correct a location error:

1.Use the arrow buttons to navigate to Fix This, and press OK.

2.Review and complete the corrective action suggested by the Insight Display. Remove the indicated component, and install it into the correct bay. The Insight Display will indicate the correct bay number.

Configuration errors

Configuration errors can occur if the interconnect modules are installed in the wrong bays or if mezzanine cards are installed in the wrong connectors in the blade. Configuration errors can occur on blades and interconnect modules.

To correct a configuration error:

1.Use the arrow buttons to navigate to Fix This, and press OK.

2.Review and complete the corrective action suggested by the Insight Display. Depending on the error received, do one of the following:

o Remove the indicated interconnect module and install it into the correct bay (the Insight Display indicates the correct bay).

o Remove the blade to correct the mezzanine card installation (the Insight Display will indicate the correct bay). For information on installing the mezzanine card, see the server-specific user guide on the Documentation CD.

Device failure errors

Device failure errors occur when a component has failed. Device failure errors can occur on all components, including:

Server blades

Storage blades

Power supplies

Interconnect modules

Onboard Administrator modules

Troubleshooting 81