217.7kg

480 lb

WARNING: To reduce the risk of personal injury or damage to the equipment:

Observe local occupation health and safety requirements and guidelines for manual handling.

Obtain adequate assistance to lift and stabilize the chassis during installation or removal.

The server is unstable when not fastened to the rails.

When mounting the server in a rack, remove the power supplies and any other removable module to reduce the overall weight of the product.

CAUTION: To properly ventilate the system, you must provide at least 7.6 cm (3.0 in) of clearance at the front and back of the server.

CAUTION: The server is designed to be electrically grounded (earthed). To ensure proper operation, plug the AC power cord into a properly grounded AC outlet only.

Insight Display errors

The enclosure installation is successful when all errors are corrected. The errors in the following sections are specific to installation and initial configuration of the enclosure. To clear errors that occur after initial powerup and configuration, see the HP BladeSystem Onboard Administrator User Guide for information.

The following types of errors can occur when installing and configuring the enclosure:

Power errors (on page 80)

Cooling errors (on page 81)

Location errors (on page 81)

Configuration errors (on page 81)

Device failure errors (on page 81)

When the enclosure UID LED is off, the Insight Display is illuminated amber when any error condition exists. The navigation bar displays the following selections when an error condition exists:

Health summary icon—Displays the Health Summary screen.

Fix THIS—Suggests corrective action to clear the current error.

Next Alert—Displays the next alert, or if none exist, displays the Health Summary screen.

Previous Alert—Displays the previous alert.

Power errors

Power errors can occur because of insufficient power to bring up an enclosure. Power errors can occur on blades, storage blades, or interconnect modules.

To correct a power error:

1.Use the arrow buttons to navigate to Fix This, and press OK.

2.Review and complete the corrective action suggested by the Insight Display. In most cases, you must either add power supplies to the enclosure or remove the indicated components.

Troubleshooting 80