Mapping half-height blades

The following table lists the available configurations for half-height devices installed in device bay N (1–16).

Connection

Port number

Connects to interconnect

Comments

 

 

 

bay/port

 

 

 

 

 

 

 

 

Embedded NIC

NIC 1

1/Port N

One or two single-wide

 

 

NIC 2

2/Port N

Ethernet interconnect modules

 

 

 

 

 

 

 

Mezzanine slot 1—1x or

1x/2x port 1

3/Port N

One single-wide

 

2x cards

1x/2x port 2

4/Port N

 

interconnect module

 

 

 

 

Four port cards will only

 

 

 

 

 

connect the first two ports.

 

 

 

 

 

 

 

Mezzanine slot 1—4x

4x port 1

3/Port N

One double-wide

 

cards

 

 

 

interconnect module

 

 

 

 

Only port 1 of a two port

 

 

 

 

 

card will be connected.

 

 

 

 

 

 

 

 

 

 

 

Installation 49