Special Procedures

Fibre Channel Arbitrated Loop Hub Monitor

Repeat Frequency: 1 day (1440 minutes)

Severity Action: Notify for all levels

The hub monitor also uses the following settings to configure the SNMP environment used by the hub. Note that two of these settings (HUB_COUNT and HUB_X_IP_ADDRESS) are required to indicate to the monitor what hubs should monitored. Changes that involve adding or deleting hubs to the configuration file while the monitor is running will be invoked at the next polling interval, or following the selection of the (E)nable Monitoring option from the Hardware Monitoring Request Manager (monconfig).

 

 

Table 6-1 PSM Configuration File Fields

 

 

 

Setting

Default

Description

 

Value

 

 

 

 

HUB_COUNT value

none

Identifies the number of hubs (value) the monitor will

 

 

be responsible for monitoring.

 

 

This setting is required.

 

 

 

HUB_X_IP_ADDRESS IP_address

none

Identifies the IP address for each hub the monitor will

 

 

monitor. The “X” placeholder is replaced by the number

 

 

assigned to the hub, and “IP_address” is replaced by the

 

 

IP address of the hub. There must be a separate setting

 

 

for each hub.

 

 

This setting is required.

 

 

 

SITE_SNMP_GET_COMMUNITY

public

These settings define the SNMP community assigned to

text

 

the hubs being monitored. The SITE setting is used for

HUB_X_SNMP_GET_COMMUNITY

 

all hubs, unless overridden by a HUB_X setting for the

text

 

specific hub identified by X.

 

 

The text string cannot contain embedded spaces.

 

 

 

SITE_LOCATION text

none

These settings define the text string used to identify the

HUB_X_LOCATION text

 

hub location in log messages. The SITE setting is used

 

 

for all hubs, unless overridden by a HUB_X setting for

 

 

the specific hub identified by X.

 

 

The text string cannot contain embedded spaces.

 

 

 

SITE_CONTACT text

none

These settings define the text string used to identify the

HUB_X_CONTACT text

 

contact person in log messages. The SITE setting is

 

 

used for all hubs, unless overridden by a HUB_X setting

 

 

for the specific hub identified by X.

 

 

The text string cannot contain embedded spaces.

 

 

 

SITE_SNMP_RETRY value

3

These settings define the SNMP retry value in seconds.

HUB_X_SNMP_RETRY value

 

The SITE setting is used for all hubs, unless overridden

 

 

by a HUB_X setting for the specific hub identified by X.

 

 

Valid values are 1 - 5.

 

 

 

SITE_SNMP_TIMEOUT value

2

These settings define the SNMP timeout value in

HUB_X_SNMP_ TIMEOUT value

 

seconds. The SITE setting is used for all hubs, unless

 

 

overridden by a HUB_X setting for the specific hub

 

 

identified by X.

 

 

Valid values are 1 - 5.

 

 

 