HP EMS HARDWARE S B6191-90028 manual PSM Configuration File

Models: EMS HARDWARE S B6191-90028

1 115
Download 115 pages 38.27 Kb
Page 106
Image 106

Special Procedures

Fibre Channel Arbitrated Loop Hub Monitor

 

 

Table 6-1 PSM Configuration File Fields

 

 

 

Setting

Default

Description

 

Value

 

 

 

 

HUB_X_IS_MONITORED value

1 (Yes)

This setting determines if the indicated hub will be

 

 

monitored.

 

 

Valid values are 0 (No) and 1 (Yes).

 

 

 

HUB_X_SYSNAME text

none

Identifies the hub's sysname if the hub's

 

 

system.sysName value is not set.

 

 

 

PSM Configuration File

File name: /var/stm/config/tools/monitor/dm_fc_hub.psmcfg

Default settings:

PSM Resource Name: /connectivity/status/hubs/FC_hub

State Handling: Requires the use of set_fixed to set UP state.

DOWN state mapping: Serious and Critical map to DOWN.

106

Chapter 6

Page 106
Image 106
HP EMS HARDWARE S B6191-90028 manual PSM Configuration File