HP EMS HARDWARE S B6191-90028 Sample Global Configuration File, Event Definition, Severity Action

Models: EMS HARDWARE S B6191-90028

1 115
Download 115 pages 38.27 Kb
Page 89
Image 89

Hardware Monitor Configuration Files

Monitor Configuration Files

Event Definition

You may want to alter the event definition in a monitor-specific configuration file to change the severity level assigned to an event, or to suppress reporting of an event.

NOTE

Be aware that any changes you make to the event definition will impact all instances of the

 

monitor's hardware resources. You cannot modify the behavior of a specific hardware resource.

 

For example, if a disk array is repeatedly reporting the same event and you would like to

 

suppress it, you can do so by changing the event definition. But the change will suppress that

 

event even if it occurs on a different disk array. This may not be the result you want.

 

 

Changing the severity level assigned to an event. If you feel that the severity level assigned to an event does not reflect its importance in your environment, you can make the event more or less important. For example, if an event is currently assigned a severity level of MAJOR WARNING but from experience you feel it represents a CRITICAL condition, you can change the DEFINE_EVENT setting for the event.

Ignoring an event. By default, all events are reported. If you are getting repeated notification for an event, you can ignore the event. When the condition that caused the event is corrected, you can once again set the event for notification.

Severity Action

By default, all severity levels are reported to EMS. This default was selected because even lower level events such as INFORMATION may provide valuable data for identifying trends that could lead to more serious conditions. Consequently, it is recommended that you do not suppress the reporting of any events.

However, if you do want to suppress the reporting of less important events, you can change the severity action to IGNORE. This will affect all events in that category, and all instances of the monitor's hardware resources.

Polling Interval

If you need more frequent polling to isolate a potential problem with the hardware, the polling interval can be reduced. Be aware that more frequent polling may impact system performance, so you may want to shorten the polling period only temporarily until the problem is solved. Avoid using a low polling interval for all monitors or system performance may suffer.

Repeat Frequency

If you need to be alerted to an event frequently, the repeat frequency can be reduced. The default repeat frequency is once a day.

Sample Global Configuration File

The following sample shows a portion of the global monitor configuration file.

#-

#Global.cfg: Sentinel Global Configuration File

#-

POLL_INTERVAL

60

#

in

minutes

(one

hour)

REPEAT_FREQUENCY

1440

#

in

minutes

(one

day)

#-

#DEFAULT ACTIONS FOR EACH SEVERITY

#(Action can be NOTIFY or IGNORE)

#-

SEVERITY_ACTION

CRITICAL

NOTIFY

SEVERITY_ACTION

SERIOUS

NOTIFY

Chapter 5

89

Page 89
Image 89
HP EMS HARDWARE S B6191-90028 manual Sample Global Configuration File, Event Definition, Severity Action, Polling Interval