Hardware Monitor Configuration Files

Monitor Configuration Files

File Names

Global configuration file: /var/stm/config/tools/monitor/Global.cfg

The file naming convention for the startup configuration files is:

/var/stm/config/tools/monitor/monitor_name.cfg

monitorname is the name of the monitor executable

File Format

Settings in the device configuration file use the following conventions:

Configuration settings consist of a term defining the characteristic to be configured, followed by a value assigned to the term.

For example, POLL_INTERVAL 60

There must be at least one space between the term and each value.

Comments begin with the pound character (#) and continue until the end of the line. A comment may occur on a line by itself, or after a blank space following the value in a configuration entry.

For example, either of the following are valid comments:

# Valid values for severity_name are:

SEVERITY_ACTION CRITICAL NOTIFY # notify on critical events

Table 5-1lists the common fields used to define monitor configuration settings. In addition to the common parameters, some monitors include other parameters in their configuration file. Any additional configuration parameters used by each monitor are listed in the monitor descriptions in the data sheets for the hardware event monitors available on the Web at http://docs.hp.com/hpux/onlinedocs/diag/ems/emd_summ.htm.

NOTE

An HP-UX man page is available for each monitor. To access the man page, type (where

 

monitorname is the executable file listed in the data sheet): man monitorname

 

 

 

 

 

Table 5-1

 

Monitor Configuration File Entries

 

 

 

 

 

 

 

 

Setting

Values

Description

 

 

 

 

 

 

 

SEVERITY_ACTION

Valid severity values

Defines whether the

 

 

<severity> <action>

are:

monitor should report or

 

 

 

CRITICAL

ignore events for the

 

 

 

indicated severity level.

 

 

 

SERIOUS

 

 

 

 

 

 

 

MAJOR_WARNING

 

 

 

 

MINOR_WARNING

 

 

 

 

INFORMATIONAL

 

 

 

 

Valid action values are:

 

 

 

 

NOTIFY

 

 

 

 

IGNORE

 

 

 

 

 

 

Chapter 5

87

Page 87
Image 87