Hardware Monitor Configuration Files

Startup Configuration File

Considerations for Modifying the Startup Configuration File Settings

While you can edit the contents of the startup configuration file directly, the better approach is to use the Hardware Monitoring Request Manager (monconfig) to create and manage your monitoring requests. Using the monitoring request manager you can create requests for multiple monitors simultaneously. And the Hardware Monitoring Request Manager ensures that all request entries are formatted correctly.

The only benefit that editing the configuration file offers is that you can use the COMMENT setting to add information that will be included with the event.

Table 5-2

Startup Configuration File Entries

 

 

 

 

 

 

Keyword

Values

Description

 

 

 

 

 

MONITOR (required)

A valid event monitor

Identifies the hardware

 

 

resource path

event monitor to which

 

 

 

the entry applies. All

 

 

 

entries must use the

 

 

 

resource path for the

 

 

 

monitor being

 

 

 

configured.

 

 

 

Note: This must the first

 

 

 

keyword in each entry

 

 

 

 

 

Criteria Threshold (required)

Valid values include:

Defines the severity

 

 

CRITICAL

level used as the

 

 

notification criteria

 

 

SERIOUS

 

 

threshold.

 

 

MAJOR_WARNING

 

 

 

 

 

MINOR_WARNING

 

 

 

INFORMATIONAL

 

 

 

 

 

 

Criteria Operator (required)

Valid operators are:

This value identifies the

 

 

%< (less than)

arithmetic operator

 

 

used with the criteria

 

 

%<= (less than or equal to

 

 

threshold to control

 

 

)

 

 

what events are

 

 

> (greater than)

 

 

reported. The operator

 

 

>= (greater than or equal

 

 

treats each severity

 

 

to)

 

 

level as a numeric value

 

 

! (not equal to)

 

 

assigned as follows:

 

 

 

 

 

 

Critical = 5

 

 

 

Serious = 4

 

 

 

Major warning = 3

 

 

 

Minor warning = 2

 

 

 

Informational = 1

 

 

 

The event severity

 

 

 

received is the left

 

 

 

operand and the

 

 

 

Criteria Threshold value

 

 

 

is the right operand.

 

 

 

 