HP EMS HARDWARE S B6191-90028 2PSM Configuration File Fields, Setting Default Description Value

Models: EMS HARDWARE S B6191-90028

1 115
Download 115 pages 38.27 Kb
Page 110
Image 110

Special Procedures

Fibre Channel Switch Monitor

what switches should monitored. Changes that involve adding or deleting switches to the configuration file while the monitor is running will be invoked at the next polling interval, or following the selection of the (E)nable Monitoring option from the Hardware Monitoring Request Manager (monconfig).

 

 

Table 6-2PSM Configuration File Fields

 

 

 

Setting

Default

Description

 

Value

 

 

 

 

SW_COUNT value

none

Identifies the number of switches (value) the

 

 

monitor will be responsible for monitoring.

 

 

This setting is required.

 

 

 

SW_X_IP_ADDRESS IP_address

none

Identifies the IP address for each switch the monitor

 

 

will monitor. The “X” placeholder is replaced by the

 

 

number assigned to the switch, and “IP_address” is

 

 

replaced by the IP address of the switch. There must

 

 

be a separate setting for each switch.

 

 

This setting is required.

 

 

 

SITE_SNMP_GET_COMMUNITY text

public

These settings define the SNMP community

SW_X_SNMP_GET_COMMUNITY text

 

assigned to the switches being monitored. The SITE

 

 

setting is used for all switches, unless overridden by

 

 

a SW_X setting for the specific switch identified by

 

 

X.

 

 

The text string cannot contain embedded spaces.

 

 

 

SITE_LOCATION text

none

These settings define the text string used to identify

SW_X_LOCATION text

 

the switch location in log messages. The SITE

 

 

setting is used for all switches, unless overridden by

 

 

a SW_X setting for the specific switch identified by

 

 

X.

 

 

The text string cannot contain embedded spaces.

 

 

 

SITE_CONTACT text

none

These settings define the text string used to identify

SW_X_CONTACT text

 

the contact person in log messages. The SITE

 

 

setting is used for all switches, unless overridden by

 

 

a SW_X setting for the specific switch identified by

 

 

X.

 

 

The text string cannot contain embedded spaces.

 

 

 

SITE_SNMP_RETRY value

1

These settings define the SNMP retry value in

SW_X_SNMP_RETRY value

 

seconds. The SITE setting is used for all switches,

 

 

unless overridden by a SW_X setting for the specific

 

 

switch identified by X.

 

 

Valid values are 1 - 5.

 

 

 

SITE_SNMP_TIMEOUT value

1

These settings define the SNMP timeout value in

SW_X_SNMP_ TIMEOUT value

 

seconds. The SITE setting is used for all switches,

 

 

unless overridden by a SW_X setting for the specific

 

 

switch identified by X.

 

 

Valid values are 1 - 5.

 

 

 

SW_X_IS_MONITORED value

1 (Yes)

This setting determines if the indicated switch will

 

 

be monitored.

 

 

Valid values are 0 (No) and 1 (Yes).

 

 

 

110

Chapter 6

Page 110
Image 110