HP EMS HARDWARE S B6191-90028 manual #Pollinterval

Models: EMS HARDWARE S B6191-90028

1 115
Download 115 pages 38.27 Kb
Page 91
Image 91

Hardware Monitor Configuration Files

Monitor Configuration Files

#POLL_INTERVAL

5

#

polling interval in

minutes

#REPEAT_FREQUENCY

1440

#

in minutes, for one

day

#****************************************************************************#

#* This list of default

actions for each

severity also

appears in the

*#

#*

global configuration

file, and should

not generally

appear here.

*#

#*

It is shown for documentation purposes.

 

*#

#****************************************************************************#

#SEVERITY_ACTION

INFORMATION

NOTIFY

#SEVERITY_ACTION

MINOR_WARNING

NOTIFY

#SEVERITY_ACTION

MAJOR_WARNING

NOTIFY

#SEVERITY_ACTION

SERIOUS

NOTIFY

#SEVERITY_ACTION

CRITICAL

NOTIFY

#****************************************************************************# #* cfg-verb event# severity- action- -description- *# #****************************************************************************#

DEFINE_EVENT

101

CRITICAL

DEFAULT # The disk is

indicating a fault

DEFINE_EVENT

102

CRITICAL

DEFAULT # The disk is

not on the FC link

DEFINE_EVENT

201

CRITICAL

DEFAULT # The power supply has faulted

DEFINE_EVENT

202

CRITICAL

DEFAULT # The power supply is not recieving adequate AC

DEFINE_EVENT

301

CRITICAL

DEFAULT # The fan is not providing cooling

DEFINE_EVENT

302

CRITICAL

DEFAULT # Temperature

has exceeded critial threshold

DEFINE_EVENT

303

MAJOR_WARNING

DEFAULT # Temperature

has exceeded warning threshold

DEFINE_EVENT

304

CRITICAL

DEFAULT # Temperature

has exceeded low critial threshold

DEFINE_EVENT

305

MAJOR_WARNING DEFAULT # Temperature

has exceeded low warning threshold

DEFINE_EVENT

306

MAJOR_WARNING

DEFAULT # Temperature

sensor may have failed

DEFINE_EVENT

401

CRITICAL

DEFAULT # The enclosure services controller has failed

DEFINE_EVENT

501

CRITICAL

DEFAULT # The SCSI port/transceiver has lost the link

DEFINE_EVENT

502

CRITICAL

DEFAULT # The transmit signal has been lost

DEFINE_EVENT

601

CRITICAL

DEFAULT # Over voltage critical threshold exceeded

DEFINE_EVENT

602

MAJOR_WARNING

DEFAULT # Over voltage warning threshold exceeded

DEFINE_EVENT

603

CRITICAL

DEFAULT # Under voltage critical threshold exceeded

DEFINE_EVENT

604

MAJOR_WARNING DEFAULT # Under voltage warning threshold exceeded

DEFINE_EVENT

605

MAJOR_WARNING DEFAULT # Voltage sensor may have failed

Chapter 5