Appendix B LEDs

HP HSR6800 routers provide LEDs for FRUs to indicate their operating status.

MPU and switching fabric module LEDs

Figure 100 RSE-X2 LEDsTable 42 RSE-X2 LED description

LED

 

Status

Description

 

 

Off

No CF card is present or the CF card is not recognizable.

 

 

 

 

 

 

Steady on

A CF card is in position and has been detected.

 

 

 

 

 

CF

 

The system is accessing the CF card.

 

 

 

(green)

 

Flashing

CAUTION:

 

 

 

 

 

 

In this state, do not insert or remove the CF card. Otherwise, the

 

 

 

file system on the CF card will be damaged.

 

 

Off

No link is present on the port.

 

 

 

 

 

LINK

Steady green

A 1000 Mbps link is present.

(green/orange)

 

 

 

 

Steady orange

A 10/100 Mbps link is present.

 

 

 

 

 

 

Off

No data is being received or transmitted.

 

ACT

 

 

 

Flashing

Data is being received or transmitted at a rate of

 

 

(yellow)

 

10/100/1000 Mbps.

 

 

 

 

 

 

 

 

Off

The system is operating correctly and there is no alarm.

 

ALM

 

 

 

Steady on

A fault has occurred to the system. In this state, check the

 

 

(red)

 

system log immediately.

 

 

 

 

 

 

 

PAL

Off

The system power supply is operating correctly.

 

 

 

 

 

The available power is not efficient, or power modules of

(red)

M

Steady on

 

different specifications are inserted.

 

 

109