HIM/MIM failures

When a HIM/MIM is plugged while the router is running, the following information might appear on the configuration terminal:

%Jun 14 11:12:36:037 2012 HP DRVICOUT/1/DrvIcOutStr: -Slot=4; Card in Slot 4 Sublot 1 can not be recognized !

The output indicates that the HIM/MIM is faulty or the router cannot recognize the HIM/MIM. To troubleshoot the HIM/MIM failure:

1.Verify that the HIM/MIM is firmly seated.

2.Verify that the HIM is correctly plugged into an FIP-210/FIP-600 module. An FIP-110 module does not support a HIM.

3.Verify that the MIM is correctly plugged into an FIP-110/FIP-210 module. An FIP-600 module does not support an MIM.

4.Verify that the HIM/MIM connector pins of the FIP module are not bent.

5.If the cause cannot be located in the steps above and the problem persists, contact your local sales agent.

Configuration system problems

If the configuration environment setup is correct, the configuration terminal displays boot information when the router is powered on. If the setup is incorrect, the configuration terminal displays nothing or garbled text.

No terminal display

If the configuration terminal displays nothing when the router is powered on, follow these steps to troubleshoot the failure:

1.Verify the following items.{The power supply system is operating correctly.{The console cable is correctly connected.2.If no problem is found, the following reasons might apply:

{The console cable is connected to an incorrect serial port. (The serial port in use is not the one set on the terminal.)

{The properties of the terminal are incorrect. You must configure the console terminal as follows: set Bits per second to 9600, Data bits to 8, Parity to None, Stop bits to 1, Flow control to None, and Terminal Emulation to VT100.

{The console cable fails.

3.If the cause cannot be located in the steps above and the problem persists, contact your local sales agent.

Garbled terminal display

If terminal display is garbled, follow these steps to solve this problem:

71