Figure 3 Airflow through the HSR6808 chassis

EMI

Electromagnetic interference (EMI) might be coupled from the source to the router through the following coupling mechanisms:

Capacitive coupling

Inductive coupling

Radiative coupling

Common impedance coupling

Conductive coupling

To prevent EMI, take the following actions:

Take measures against interference from the power grid.

Do not use the router together with the grounding equipment or lightning-prevention equipment of power equipment, and keep the router far away from them.

Keep the router far away from high-power radio launchers, radars, and equipment with high frequency or high current.

Use electromagnetic shielding when necessary.