Field

Description

 

Fan state:

State

Normal—The fan is operating correctly.

Absent—The fan is not in position.

 

 

Fault—The fan has failed.

 

 

Displaying the power module operating status

Use the display power command to display the power module operating status.

<Sysname> display power System Power Total System Power Used System Power Usable

:650 watts

:275 watts

:375 watts

Power No.

Type

Watts

State

ID

---------------------------------------------

1

N/A

N/A

Absent

N/A

2

AC

650

Normal

0

Table 17 Command output

 

 

 

 

 

 

 

Field

 

Description

 

System Power Total

Total power provided by the power modules.

 

 

 

System Power Used

Power in use.

 

 

 

System Power Usable

Power available for use.

 

 

 

Power No.

 

Slot number of the power module.

 

 

 

 

 

Power module type:

Type

 

AC—AC power modules.

 

 

DC—DC power modules.

 

 

 

Watts

 

Power provided by the power module.

 

 

 

 

ID

 

Power module ID.

 

 

 

 

 

 

Power module state:

State

Normal—The power module is operating correctly.

Absent—The power module is not in position.

Fault—The power module has failed.

Displaying the alarming thresholds of a card

Use the display environment command to display the temperature information and alarming thresholds of a card.

<Sysname> display environment

Temperature information (degree centigrade):

----------------------------------------------------------

SlotNo

Temperature

Lower limit

Upper limit

61