SCSI Sense Codes

 

 

 

Table A-3

SCSI Additional Sense Code/Qualifier Code Pairs (Continued)

 

 

 

 

 

SCSI

SCSI

 

 

Additional

 

 

Qualifier

Meaning

 

Sense

 

Code

 

 

Code

 

 

 

 

 

 

 

 

 

0x21

0x00

Logical block address out of range

 

 

 

 

 

 

0x01

Invalid element address

 

 

 

 

 

0x22

0x00

Illegal function

 

 

 

 

 

0x24

0x00

Invalid field in cdb

 

 

 

 

 

0x25

0x00

Logical unit not supported

 

 

 

 

 

0x26

0x00

Invalid field in parameter list

 

 

 

 

 

 

0x01

Parameter not supported

 

 

 

 

 

 

0x02

Parameter value invalid

 

 

 

 

 

 

0x03

Threshold parameters not supported

 

 

 

 

 

0x27

0x00

Write protected

 

 

 

 

 

0x28

0x00

Not ready to ready transition (medium

 

 

 

may have changed)

 

 

 

 

 

 

0x01

Import or export element assessed

 

 

 

 

 

0x29

0x00

Power on, reset, or bus device reset

 

 

 

occurred

 

 

 

 

 

0x2a

0x00

Parameters changed

 

 

 

 

 

 

0x01

Mode parameters changed

 

 

 

 

 

 

0x02

Log parameters changed

 

 

 

 

 

0x2b

0x00

Copy cannot execute since host cannot

 

 

 

disconnect

 

 

 

 

 

0x2c

0x00

Command sequence error

 

 

 

 

 

 

0x01

Too many windows specified

 

 

 

 

102

Appendix A

Page 116
Image 116
HP I Dual Channel Ultra160 SCSI Host Adapter A6829A manual 102