Troubleshooting
Setting and Confirming SCSI Parameters
LSI Logic Host Bus Adapters |
|
|
| |||
Adapter | PCI | PCI | PCI | IRQ | NVM | LSI Logic |
| Bus | Device | Function |
|
| Control |
<53C875 | 60 | 01 | 01> | 0 | Yes | Enabled |
Press the [Enter] key. This displays the Adapter Properties screen containing the controller (HBA) settings; refer to the following example:
Adapter Properties
Adapter | PCI | PCI | PCI |
| Bus | Device | Function |
53C875 | 60 | 01 | 01 |
<Device Properties> |
|
Boot Support | [Enabled] |
SCSI Parity | [Yes] |
Host SCSI ID | [ 5] |
SCSI Bus Scan Order | [Low to High (0..Max)] |
Spinup Delay (Secs) | [ 2] |
Secondary Cluster Server | [Yes] |
Termination Control | [Auto] |
<Restore Defaults> |
|
Use the arrow keys to highlight the different SCSI parameters.
Use the plus (+) and minus
NOTE | Modify only the Host SCSI ID and the Secondary Cluster Server |
| parameters, if necessary. |
| Set the Secondary Cluster Server to Yes if more than one initiator is |
| connected to the SCSI bus. |
| Do not change the default values of other SCSI parameters listed on the |
| screen. |
|
|
82 | Chapter 3 |