Installing the A6829A Adapter

Specifying SCSI Parameters

 

Setting SCSI Parameters to Default Values

 

You can set the SCSI parameters, except Auto Termination, for the

 

adapter to their default values through the BCH menus. The steps you

 

follow depend on the type of HP-UX system in which the adapter is

 

installed.

 

hp servers rp7410, rp8400, and superdome

 

On hp servers rp7410, rp8400, and superdome, set the SCSI parameters

 

to the default values by performing the following steps:

Step

1. If you are already at the “Main Menu,” type ser (for “Service Menu”); go

 

to step 2.

 

If you are not at the “Main Menu,” type main (to return to the “Main

 

Menu”), type ser (for “Service Menu”), and then go to step 2.

Step

2. In the “Service Menu,” type the following command:

 

scsi path default

 

where, path is the HBA’s path. This sets all of the SCSI parameters for

 

the path to their default values.

Step

3. Type main to get back to the “Main Menu.”

 

All Other Servers

 

On all servers other than hp servers rp7410, rp8400, and superdome, set

 

the SCSI parameters to the default values by following the steps for

 

specifying each SCSI parameter (described earlier in this section).

 

You will need to know the default value—and how to specify it—for each

 

SCSI parameter. To know the valid SCSI parameter values, HP

 

recommends you to use the online help for the scsi command (type

 

help scsi when you are in the BCH “Service Menu”).