If the message still appears, follow the drive manufacturer's instructions to make sure the drive is set to spin up when the power is switched ON.

Start unit request failed

The BIOS was unable to send a Start Unit Command to the device. Run the SCSISelect utility and disable Send Start Unit Command for the device.

Time-out failure during …

An unexpected time-out occurred. Check SCSI bus termination. Try disconnecting the SCSI peripheral cables from the host adapter and then starting the HP Netserver. If the HP Netserver successfully restarts, check SCSI bus termination and cable connections. One of the devices on the SCSI bus may be defective.

Attention! Too many devices are terminated on the SE connectors

The SCSI host bus adapter BIOS has detected that more than two devices have been terminated on the narrow SE SCSI segment. Verify the termination on the devices connected to the internal and external connectors. Terminate only the SCSI device at the ends of the cable. Remove or disable the terminators on the SCSI devices between the ends of the cable.

Attention! Insufficient termination detected on the SE connectors

The SCSI host bus adapter BIOS has detected that either only one or no devices have been terminated on the narrow SE SCSI segment. Verify the termination on the devices connected to the internal and external connectors. Terminate only the SCSI device at the ends of the cable. Remove or disable any terminators on the SCSI devices between the ends of the cable.

NOTE The termination detection feature is only implemented on the internal narrow SE connectors. The 68-pin LVD/SE connector does not support this feature.