3.7A/D Range and Status Read back Register

The A/D range setting and A/D FIFO status can be read back from this register.

Address: BASE + 8h

Attribute: read only

Data Format:

 

Bit

 

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

BASE+8h

 

AD_BUSY

FF_FF

FF_HF

FF_EF

0

G2

G1

G0

 

BASE+9h

 

X

X

X

X

X

X

X

X

Where

 

 

 

 

 

 

 

 

 

GC0~GC2:

A/D Range control setting

 

 

 

 

 

 

FF_EF:

‘0’ means FIFO is empty

 

 

 

 

 

 

FF_HF:

‘0’ means FIFO is half-full

 

 

 

 

 

 

FF_FF:

‘0’ means FIFO is full, A/D data may have been loss

 

AD_BUSY:

‘0’ means AD is busy, the A/D data has not been latched

 

 

 

in FIFO yet. If AD_BUSY changes from ‘0’ to ‘1’, A/D is

 

 

 

not busy and the data is written into FIFO.

 

 

 

3.8A/D Trigger Mode Control Register

This register is used to control the A/D trigger source and trigger method.

Address: BASE + 0Ah

Attribute: write only

Data Format:

Bit

7

6

5

4

 

3

 

2

1

0

 

 

 

 

 

 

 

 

 

BASE+0Ah

X

X

X

X

 

PTRG

 

EITS

TPST

ASCAN

BASE+0Bh

X

X

X

X

 

X

 

X

X

X

PTRG:

Pre-trigger ON/OFF control

 

 

 

 

0: Pre-trigger OFF

 

 

 

 

 

 

1: Pre-Trigger ON

 

 

 

 

 

EITS:

External / Internal Trigger Source

 

 

 

 

1: External Trigger Source

 

 

 

 

0: Internal Trigger Source

 

 

 

TPST:

Timer Pacer/ Software Trigger

 

 

 

 

0: Software Trigger

 

 

 

 

 

 

1: Timer Pacer Trigger

 

 

 

 

 

Registers Format 17

Page 27
Image 27
HP NuDAQ I-9111DG/HR manual A/D Range and Status Read back Register, A/D Trigger Mode Control Register