5.44_9111_AD_INT_Stop

@ Description

This function is used to stop both the interrupt data transfer functions. After executing this function, the internal AD trigger is disabled and the AD timer is stopped. This function returns the number/block of data has been transferred, no matter whether the AD interrupt data transfer is stopped by this function.

@ Syntax

C/C++ (DOS)

U16 _9111_AD_INT_Stop (U16 cardNo, U16 *count)

C/C++ (Windows 95)

U16 W_9111_AD_INT_Stop (U16 cardNo, U16 *count)

Visual Basic (Windows 95)

W_9111_AD_INT_Stop (ByVal cardNo As Integer, count As Integer) As Integer

@ Argument:

CardNo: the card number of PCI-9111 card initialized.

count: the number/block of A/D data which has been transferred.

@ Return Code

ERR_AD_INTNotSet

ERR_NoError

64 C/C++ Library

Page 74
Image 74