Hunter Fan R410A manual Model FDKN series, Change by the jumper wire, Name, Function, Switch

Models: R410A

1 48
Download 48 pages 23.34 Kb
Page 12
Image 12
Model: FDKN series

Model: FDKN series

This diagram shows the PCB for the 151~251. The component layout on the 301 PCB is different, but the functions are the same.

J31

 

Heat exchanger thermistor,

 

Heat exchanger thermistor

Return air thermistor

Remote controller

(Thl-R1, Thl-A)

 

(Thl-R2)

 

 

 

 

 

TB,3

 

R16

 

Dip switch (SW5)

J9~J11

(SW10)

Dip switch (SW9)

J5~J8

(SW8)

J1~J4(SW7)

CNZ

SW10 SW5

J9

J10

J11

SW8 SW9

J5

J6

J7

J8

J4 J3 J2 J1

SW7

CNE

CNN1

 

CNH

R17

 

CNB

L1

L2

 

 

 

J31

 

 

 

 

 

 

CNW1

 

 

IC11

 

 

L4

 

 

R151

TB,2

TB,1

G

PCB power supply connector

(Primary side)

Adress switch (SW2)

SW2

IC9IC10

 

C92

LED1

CNG

 

CNL

CNY

 

C2

 

R62

 

IC8

 

BZ

 

CNT

CNJ

CNM

C104

PCB power supply connector

(Secondary side)

Louver motor

Connector

Fan motor

(CNT)

 

 

 

Change by the jumper wire

 

Name

Function

J1 (SW7-1)

 

With

Input signal - Reverse invalid

 

None (1)

Input signal - Rus stop

 

 

J2 (SW7-2)

 

With

Heating thermostat OFF-Lo

 

None (1)

Heating thermostat OFF-Stop, Lo

 

 

J3 (SW7-3)

 

With

Normal operation operable

 

None (1)

Operation permission prohibited

 

 

J4 (SW7-4)

 

With

Normal

 

None (1)

Heating temp. +3

 

 

J5 (SW8-1)

 

With

Louver free stop control - Invalid

 

None (1)

Louver free stop control - Effective

 

 

J6 (SW8-2)

 

With

Freeze prevention fan control activated.

 

None (1)

Freeze prevention fan control deactivated.

 

 

J8 (SW8-4)

 

With

Model 151~251

 

None (1)

Model 301

 

 

Note (1) “None” means that jumper wire is not provided on the PCB or the connection is cut

(2)The replacement board is not equipped with jumpers J1 ~ J8. Instead, SW7 and 8, with the same functions as jumpers J1~J8, are used in the position where the jumpers were previously. Set SW7 and 8 locally in accordance with the above table.

Control change switch (SW5, SW9, SW10)

Function of DIP switch SW5 (Usually all turned OFF)

 

Switch

 

Function

 

ON

 

ON

Setting time : 1000hrs. (Unit stop)

SW5-3

SW5-4

OFF

Setting time : 1000hrs. (Display)

 

OFF

ON

Setting time : 600hrs. (Display)

 

 

 

 

OFF

Setting time : 180hrs. (when shipped from factory)

 

 

 

Function of DIP switch SW9 (Usually all turned OFF)

 

Switch

Function

SW9-1

 

OFF

Custom code - Change

 

ON

Custom code - Normal

 

 

SW9-2

 

OFF

Power failure security - Effective

 

ON

Power failure security - Invalid

 

 

SW9-3

 

ON

Emergency operation

 

OFF

Normal

 

 

SW9-4

 

ON

Fan control : Powerful mode

 

OFF

Fan control : Mild mode

 

 

Note (1) It is normally ON only in the case of SW9-4.

Function of DIP switch SW10 (Usually all turned OFF)

 

Switch

 

Function

SW10-1 (J9)

OFF

Auto swing fanction - None

 

ON

Auto swing function - With

 

 

 

 

 

 

OFF

 

OFF

Remote controller air flow

SW10-2

SW10-3

ON

Remote controller air flow

1 speed

 

(J10)

ON

(J11)

OFF

Remote controller air flow

2 speed

ON

Remote controller air flow

3 speed

 

 

 

- 10 -

Page 12
Image 12
Hunter Fan R410A manual Model FDKN series, Change by the jumper wire, Control change switch SW5, SW9, SW10, Name, Function